Add troubleshooting to readme

pull/69/head
Thorsten von Eicken 9 years ago
parent ba347a83dc
commit 948990cefb
  1. 15
      README.md

@ -295,6 +295,21 @@ or it craps out in the middle too often then try the built-in programmer with th
If your AVR doesn't use optiboot then use port 2323 since esp-link may not recognize the programming
sequence and not issue a reset if you use port 23.
If you are having trouble with the built-in programmer and see something like this:
```
# ./avrflash 192.168.3.104 blink.hex
Error checking sync: FAILED to SYNC: abandoned after timeout, got:
:\xF/\x00\xCj\xCz\xCJ\xCZ\xC\xAÜ\xC\xAä\xC\xAÜ\xC\xAä\xC\xBì\xC\xBô\xC\xBì\xC\xBô\xC\xAÜ\xC\xAä\xC\x00\xC\x00\x00\x00
\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00
\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\xF6\xF6\xF6\xF6\xC
```
the most likely cause is a baud rate mismatch and/or a bad connection from the esp8266 to the AVRs reset line.
The baud rate used by esp-link is set on the uC Console web page.
The above garbage characters are most likely due to optiboot timing out and starting the sketch and then the sketch
sending data at a different baud rate than configured into esp-link.
Note that sketches don't necessarily use the same baud rate as optiboot, so you may have the correct baud rate configured
but reset isn't functioning, or reset may be functioning but the baud rate may be incorrect.
### Flashing an attached ARM processor
You can reprogram NXP's LPC800-series and many other ARM processors as well by pointing your