You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
316 lines
14 KiB
316 lines
14 KiB
## <i class="fa fa-code"></i> Constructor
|
|
|
|
### AutoConnectConfig
|
|
|
|
```cpp
|
|
AutoConnectConfig()
|
|
```
|
|
```cpp
|
|
AutoConnectConfig(const char* ap, const char* password)
|
|
```
|
|
```cpp
|
|
AutoConnectConfig(const char* ap, const char* password, const unsigned long timeout)
|
|
```
|
|
```cpp
|
|
AutoConnectConfig(const char* ap, const char* password, const unsigned long timeout, const uint8_t channel)
|
|
```
|
|
<dl class="apidl">
|
|
<dt>**Parameters**</dt>
|
|
<dd><span class="apidef">ap</span><span class="apidesc">SSID for SoftAP. The length should be up to 31. The default value is **esp8266ap** for ESP8266, **esp32ap** for ESP32.</span></dd>
|
|
<dd><span class="apidef">password</span><span class="apidesc">Password for SodtAP. The length should be from 8 to up to 63. The default value is **12345678**.</span></dd>
|
|
<dd><span class="apidef">timeout</span><span class="apidesc">The timeout value of the captive portal in [ms] units. The default value is 0.</span></dd>
|
|
<dd><span class="apidef">channel</span><span class="apidesc">The channel number of WIFi when SoftAP starts. The default values is 1.</span></dd>
|
|
</dl>
|
|
|
|
## <i class="fa fa-code"></i> Public member variables
|
|
|
|
### <i class="fa fa-caret-right"></i> apid
|
|
|
|
SoftAP's SSID.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd><span class="apidef">String</span><span class="apidesc"> The default value is **esp8266ap** for ESP8266, **esp32ap** for ESP32.</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> apip
|
|
|
|
Sets IP address for Soft AP in captive portal. When AutoConnect fails the initial WiFi.begin, it starts the captive portal with the IP address specified this.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd><span class="apidef">IPAddress</span><span class="apidesc">The default value is **192.168.244.1**</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> autoReconnect
|
|
|
|
Automatically will try to reconnect with the past established access point (BSSID) when the current configured SSID in ESP8266/ESP32 could not be connected. By enabling this option, *AutoConnect::begin()* function will attempt to reconnect to a known access point using credentials stored in the EEPROM, even if the connection failed by current SSID.
|
|
If the connection fails, starts the captive portal in SoftAP+STA mode.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>bool</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">true</span><span class="apidesc">Reconnect automatically.</span></dd>
|
|
<dd><span class="apidef">false</span><span class="apidesc">Starts Captive Portal in SoftAP + STA mode without trying to reconnect. This is the default.</span></dd>
|
|
</dl>
|
|
|
|
When the autoReconnect option is enabled, an automatic connection will behave if the following conditions are satisfied.
|
|
|
|
- Invokes *AutoConnect::begin* without user name and password parameter as ```begin()```.
|
|
- If one of the saved BSSIDs (not the SSID) of the credentials matches the BSSID detected by the network scan.
|
|
|
|
### <i class="fa fa-caret-right"></i> autoReset
|
|
|
|
Reset ESP8266 module automatically after WLAN disconnected.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>bool</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">true</span><span class="apidesc">Reset after WiFi disconnected automatically.</span></dd>
|
|
<dd><span class="apidef">false</span><span class="apidesc">No reset.</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> autoRise
|
|
|
|
Captive portal activation switch. False for disabling the captive portal. It prevents starting the captive portal even if the connection at the first *WiFi.begin* fails.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>bool</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">true</span><span class="apidesc">Enable the captive portal. This is the default.</span></dd>
|
|
<dd><span class="apidef">false</span><span class="apidesc">Disable the captive portal.</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> autoSave
|
|
|
|
The credential saved automatically at the connection establishment.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>AC_SAVECREDENTIAL_t</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">AC_SAVECREDENTIAL_AUTO</span><span class="apidesc"></span><span class="apidef"> </span><span class="apidesc">The credential saved automatically. This is the default.</span></dd>
|
|
<dd><span class="apidef">AC_SAVECREDENTIAL_NEVER</span><span class="apidesc"></span><span class="apidef"> </span><span class="apidesc">The credential no saved.</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> bootUri
|
|
|
|
Specify the location to be redirected after module reset in the AutoConnect menu. It is given as an enumeration value of **AC_ONBOOTURI_t** indicating either the AutoConnect root path or the user screen home path.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>AC_ONBOOTURI_t</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">AC_ONBOOTURI_ROOT</span><span class="apidesc"></span><span class="apidef"> </span><span class="apidesc">Resetting the module redirects it to the AutoConnect root path. The root path is assumed to be AUTOCONNECT_URI defined in AutoConnectDefs.h.</span></dd>
|
|
<dd><span class="apidef">AC_ONBOOTURI_HOME</span><span class="apidesc"></span><span class="apidef"> </span><span class="apidesc">It is redirected to the URI specified by [**AutoConnectConfig::homeUri**](apiconfig.md#homeuri).</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> boundaryOffset
|
|
|
|
Sets the offset address of the credential storage area for EEPROM. This value must be between greater than 4 and less than flash sector size. (4096 by SDK)
|
|
The default value is 0.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>uint16_t</dd>
|
|
</dl>
|
|
|
|
!!! warning "It will conflict with user data."
|
|
If the sketch leaves this offset at zero, it will conflict the storage area of credentials with the user sketch owned data. It needs to use the behind of credential area.
|
|
|
|
### <i class="fa fa-caret-right"></i> channel
|
|
|
|
The channel number of WIFi when SoftAP starts.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>uint8_t</dd>
|
|
<dt>**Value**</dt>
|
|
<dd>1 ~ 14. The default value is 1.</dd>
|
|
</dl>
|
|
|
|
!!! info "How do I choose Channel"
|
|
Espressif Systems had announced the [application note](https://www.espressif.com/sites/default/files/esp8266_wi-fi_channel_selection_guidelines.pdf) about Wi-Fi channel selection.
|
|
|
|
### <i class="fa fa-caret-right"></i> dns1
|
|
|
|
Set primary DNS server address when using static IP address.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>IPAddress</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> dns2
|
|
|
|
Set secondary DNS server address when using static IP address.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>IPAddress</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> gateway
|
|
|
|
Sets gateway address for Soft AP in captive portal. When AutoConnect fails the initial WiFi.begin, it starts the captive portal with the IP address specified this.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd><span class="apidef">IPAddress</span><span class="apidesc">The default value is **192.168.244.1**</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> hidden
|
|
|
|
Sets SoftAP to hidden SSID.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>uint8_t</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">0</span><span class="aidesc">SSID will be appeared. This is the default.</span></dd>
|
|
<dd><span class="apidef">1</span><span class="apidesc">SSID will be hidden.</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> homeUri
|
|
|
|
Sets the home path of user sketch. This path would be linked from 'HOME' in the AutoConnect menu. The default for homeUri is "/".
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>String</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> hostName
|
|
|
|
Sets the station host name of ESP8266/ESP32.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>String</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> immediateStart
|
|
|
|
Disable the first WiFi.begin() and start the captive portal. If this option is enabled, the module will be in AP_STA mode and the captive portal will be activated regardless of [**AutoConnectConfig::autoRise**](apiconfig.md#autorise) specification.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>bool</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">true</span><span class="apidesc">Start the captive portal with [**AutoConnect::begin**](api.md#begin).</span></dd>
|
|
<dd><span class="apidef">false</span><span class="apidesc">Enable the first WiFi.begin() and it will start captive portal when connection failed. This is default.</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> netmask
|
|
|
|
Sets subnet mask for Soft AP in captive portal. When AutoConnect fails the initial WiFi.begin, it starts the captive portal with the IP address specified this.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd><span class="apidef">IPAddress</span><span class="apidesc">The default value is **255.255.255.0**</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> portalTimeout
|
|
|
|
Specify the timeout value of the captive portal in [ms] units. It is valid when the station is not connected and does not time out if the station is connected to the ESP module in SoftAP mode (i.e. Attempting WiFi connection with the portal function). If 0, the captive portal will not be timed-out.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd><span class="apidef">unsigned long</span><span class="apidesc">Captive portal timeout value. The default value is 0.</span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> psk
|
|
|
|
Sets password for SoftAP. The length should be from 8 to up to 63. The default value is **12345678**.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>String</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> retainPortal
|
|
|
|
Specify whether to continue the portal function even if the captive portal timed out. If the true, when a timeout occurs, the [**AutoConnect::begin**](api.md#begin) function is exited with returns false, but the portal facility remains alive. So SoftAP remains alive and you can invoke AutoConnect while continuing sketch execution. The default is false.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>bool</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">true</span><span class="apidesc">Continue the portal function even if the captive portal times out. The STA + SoftAP mode of the ESP module continues and accepts the connection request to the AP.</span></dd>
|
|
<dd><span class="apidef">false</span><span class="apidesc">When the captive portal times out, STA + SoftAP mode of the ESP module is stopped. This is default.</span></dd>
|
|
</dl>
|
|
|
|
!!! hint "Connection request after timed-out"
|
|
With the **retainPortal**, even if AutoConnect::begin in the setup() is timed out, you can execute the sketch and the portal function as a WiFi connection attempt by calling AutoConnect::handleClient in the loop().
|
|
|
|
!!! info "All unresolved addresses redirects to /_ac"
|
|
If you enable the **retainPortal** option, **all unresolved URIs will be redirected to `SoftAPIP/_ac`**. It happens frequently as client devices repeat captive portal probes in particular. To avoid this, you need to exit from the WiFi connection Apps on your device once.
|
|
|
|
### <i class="fa fa-caret-right"></i> staip
|
|
|
|
Set a static IP address. The IP will behave with STA mode.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>IPAddress</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> staGateway
|
|
|
|
Set the gateway address when using static IP address.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>IPAddress</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> staNetmask
|
|
|
|
Set the subnetmask when using static IP address.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>IPAddress</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> ticker
|
|
|
|
Set flicker signal output according to WiFi connection status during AutoConnect::begin behavior.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>bool</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">true</span><span class="apidesc">Output the flicker signal while [AutoConnect::begin](api.md#begin) operation. The **AUTOCONNECT_TICKER_PORT** macro defined in the `AutoConnectDefs.h` header file assigns pins for signal output. The default pin is arduino variants LED_BUILTIN. For boards without the LED\_BUILTIN pin, assume pin #2.</span></dd>
|
|
<dd><span class="apidef">false</span>No flicker signal output.<span class="apidesc"></span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> tickerPort
|
|
|
|
Specifies the GPIO port number to output the flicker signal of the ticker. The default assumes on the board dependent definition **LED\_BUILTIN** macro redefined by **AUTOCONNECT\_TICKER\_PORT** in `AutoConnectDefs.h`.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>uint8_t</dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> tickerOn
|
|
|
|
Specifies the active logic level of the flicker signal. This value indicates the active signal level when driving the ticker.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>uint8_t</dd>
|
|
<dt>**Value**</dt>
|
|
<dd><span class="apidef">LOW</span>A flicker signal is an active-high.<span class="apidesc"></span></dd>
|
|
<dd><span class="apidef">HIGH</span>A flicker signal is an active-low.<span class="apidesc"></span></dd>
|
|
</dl>
|
|
|
|
### <i class="fa fa-caret-right"></i> title
|
|
|
|
Set the menu title.
|
|
<dl class="apidl">
|
|
<dt>**Type**</dt>
|
|
<dd>String</dd>
|
|
</dl>
|
|
|
|
## <i class="fa fa-code"></i> AutoConnectConfig example
|
|
|
|
```cpp
|
|
AutoConnect Portal;
|
|
AutoConnectConfig Config("", "passpass"); // SoftAp name is determined at runtime
|
|
Config.apid = ESP.hostname(); // Retrieve host name to SotAp identification
|
|
Config.apip = IPAddress(192,168,10,101); // Sets SoftAP IP address
|
|
Config.gateway = IPAddress(192,168,10,1); // Sets WLAN router IP address
|
|
Config.netmask = IPAddress(255,255,255,0); // Sets WLAN scope
|
|
Config.autoReconnect = true; // Enable auto-reconnect
|
|
Config.autoSave = AC_SAVECREDENTIAL_NEVER; // No save credential
|
|
Config.boundaryOffet = 64; // Reserve 64 bytes for the user data in EEPROM.
|
|
Config.portalTimeout = 60000; // Sets timeout value for the captive portal
|
|
Config.retainPortal = true; // Retains the portal function after timed-out
|
|
Config.homeUri = "/index.html"; // Sets home path of the sketch application
|
|
Config.title ="My menu"; // Customize the menu title
|
|
Config.staip = IPAddress(192,168,10,10); // Sets static IP
|
|
Config.staGateway = IPAddress(192,168,10,1); // Sets WiFi router address
|
|
Config.staNetmask = IPAddress(255,255,255,0); // Sets WLAN scope
|
|
Config.dns1 = IPAddress(192,168,10,1); // Sets primary DNS address
|
|
Portal.config(Config); // Configure AutoConnect
|
|
Portal.begin(); // Starts and behaves captive portal
|
|
```
|
|
|