## Constructor
### AutoConnectConfig
```cpp
AutoConnectConfig()
```
```cpp
AutoConnectConfig(const char* ap, const char* password)
```
```cpp
AutoConnectConfig(const char* ap, const char* password, const unsigned long timeout)
```
```cpp
AutoConnectConfig(const char* ap, const char* password, const unsigned long timeout, const uint8_t channel)
```
- **Parameters**
- apSSID for SoftAP. The length should be up to 31. The default value is **esp8266ap** for ESP8266, **esp32ap** for ESP32.
- passwordPassword for SodtAP. The length should be from 8 to up to 63. The default value is **12345678**.
- timeoutThe timeout value of the captive portal in [ms] units. The default value is 0.
- channelThe channel number of WIFi when SoftAP starts. The default values is 1.
## Public member variables
### apid
SoftAP's SSID.
- **Type**
- String The default value is **esp8266ap** for ESP8266, **esp32ap** for ESP32.
### apip
Sets IP address for Soft AP in captive portal. When AutoConnect fails the initial WiFi.begin, it starts the captive portal with the IP address specified this.
- **Type**
- IPAddressThe default value is **172.217.28.1**
### autoReconnect
Automatically will try to reconnect with the past established access point (BSSID) when the current configured SSID in ESP8266/ESP32 could not be connected. By enabling this option, *AutoConnect::begin()* function will attempt to reconnect to a known access point using credentials stored in the flash, even if the connection failed by current SSID.
If the connection fails, starts the captive portal in SoftAP+STA mode.
- **Type**
- bool
- **Value**
- trueReconnect automatically.
- falseStarts Captive Portal in SoftAP + STA mode without trying to reconnect. This is the default.
When the autoReconnect option is enabled, an automatic connection will behave if the following conditions are satisfied.
- Invokes *AutoConnect::begin* without user name and password parameter as ```begin()```.
- If one of the saved BSSIDs (not the SSID) of the credentials matches the BSSID detected by the network scan.
### autoReset
Reset ESP8266 module automatically after WLAN disconnected.
- **Type**
- bool
- **Value**
- trueReset after WiFi disconnected automatically.
- falseNo reset.
### autoRise
Captive portal activation switch. False for disabling the captive portal. It prevents starting the captive portal even if the connection at the first *WiFi.begin* fails.
- **Type**
- bool
- **Value**
- trueEnable the captive portal. This is the default.
- falseDisable the captive portal.
### autoSave
The credential saved automatically at the connection establishment.
- **Type**
- AC_SAVECREDENTIAL_t
- **Value**
- AC_SAVECREDENTIAL_AUTO The credential saved automatically. This is the default.
- AC_SAVECREDENTIAL_NEVER The credential no saved.
### bootUri
Specify the location to be redirected after module reset in the AutoConnect menu. It is given as an enumeration value of **AC_ONBOOTURI_t** indicating either the AutoConnect root path or the user screen home path.
- **Type**
- AC_ONBOOTURI_t
- **Value**
- AC_ONBOOTURI_ROOT Resetting the module redirects it to the AutoConnect root path. The root path is assumed to be AUTOCONNECT_URI defined in AutoConnectDefs.h.
- AC_ONBOOTURI_HOME It is redirected to the URI specified by [**AutoConnectConfig::homeUri**](apiconfig.md#homeuri).
### boundaryOffset
Sets the offset address of the credential storage area for EEPROM. This value must be between greater than 4 and less than flash sector size. (4096 by SDK)
The default value is 0.
This option is valid only for ESP8266 or ESP32 arduino core 1.0.2 earlier.
- **Type**
- uint16_t
!!! warning "It will conflict with user data."
If the sketch leaves this offset at zero, it will conflict the storage area of credentials with the user sketch owned data. It needs to use the behind of credential area.
### channel
The channel number of WIFi when SoftAP starts.
- **Type**
- uint8_t
- **Value**
- 1 ~ 14. The default value is 1.
!!! info "How do I choose Channel"
Espressif Systems had announced the [application note](https://www.espressif.com/sites/default/files/esp8266_wi-fi_channel_selection_guidelines.pdf) about Wi-Fi channel selection.
### dns1
Set primary DNS server address when using static IP address.
- **Type**
- IPAddress
### dns2
Set secondary DNS server address when using static IP address.
- **Type**
- IPAddress
### gateway
Sets gateway address for Soft AP in captive portal. When AutoConnect fails the initial WiFi.begin, it starts the captive portal with the IP address specified this.
- **Type**
- IPAddressThe default value is **172.217.28.1**
### hidden
Sets SoftAP to hidden SSID.
- **Type**
- uint8_t
- **Value**
- 0SSID will be appeared. This is the default.
- 1SSID will be hidden.
### homeUri
Sets the home path of user sketch. This path would be linked from 'HOME' in the AutoConnect menu. The default for homeUri is "/".
- **Type**
- String
### hostName
Sets the station host name of ESP8266/ESP32.
- **Type**
- String
### immediateStart
Disable the first WiFi.begin() and start the captive portal. If this option is enabled, the module will be in AP_STA mode and the captive portal will be activated regardless of [**AutoConnectConfig::autoRise**](apiconfig.md#autorise) specification.
- **Type**
- bool
- **Value**
- trueStart the captive portal with [**AutoConnect::begin**](api.md#begin).
- falseEnable the first WiFi.begin() and it will start captive portal when connection failed. This is default.
### netmask
Sets subnet mask for Soft AP in captive portal. When AutoConnect fails the initial WiFi.begin, it starts the captive portal with the IP address specified this.
- **Type**
- IPAddressThe default value is **255.255.255.0**
### portalTimeout
Specify the timeout value of the captive portal in [ms] units. It is valid when the station is not connected and does not time out if the station is connected to the ESP module in SoftAP mode (i.e. Attempting WiFi connection with the portal function). If 0, the captive portal will not be timed-out.
- **Type**
- unsigned longCaptive portal timeout value. The default value is 0.
### psk
Sets password for SoftAP. The length should be from 8 to up to 63. The default value is **12345678**.
- **Type**
- String
### retainPortal
Specify whether to continue the portal function even if the captive portal timed out. If the true, when a timeout occurs, the [**AutoConnect::begin**](api.md#begin) function is exited with returns false, but the portal facility remains alive. So SoftAP remains alive and you can invoke AutoConnect while continuing sketch execution. The default is false.
- **Type**
- bool
- **Value**
- trueContinue the portal function even if the captive portal times out. The STA + SoftAP mode of the ESP module continues and accepts the connection request to the AP.
- falseWhen the captive portal times out, STA + SoftAP mode of the ESP module is stopped. This is default.
!!! hint "Connection request after timed-out"
With the **retainPortal**, even if AutoConnect::begin in the setup() is timed out, you can execute the sketch and the portal function as a WiFi connection attempt by calling AutoConnect::handleClient in the loop().
!!! info "All unresolved addresses redirects to /_ac"
If you enable the **retainPortal** option, **all unresolved URIs will be redirected to `SoftAPIP/_ac`**. It happens frequently as client devices repeat captive portal probes in particular. To avoid this, you need to exit from the WiFi connection Apps on your device once.
### staip
Set a static IP address. The IP will behave with STA mode.
- **Type**
- IPAddress
### staGateway
Set the gateway address when using static IP address.
- **Type**
- IPAddress
### staNetmask
Set the subnetmask when using static IP address.
- **Type**
- IPAddress
### ticker
Set flicker signal output according to WiFi connection status during AutoConnect::begin behavior.
- **Type**
- bool
- **Value**
- trueOutput the flicker signal while [AutoConnect::begin](api.md#begin) operation. The **AUTOCONNECT_TICKER_PORT** macro in the `AutoConnectDefs.h` header file assigns pins for signal output. The default pin is arduino valiant's LED_BUILTIN. For boards without the LED_BUILTIN pin, assume pin #2.
- falseNo flicker signal output.
### tickerPort
Specifies the GPIO port number to output the flicker signal of the ticker. The default assumes on the board dependent definition LED_BUILTIN macro redefined by **AUTOCONNECT_TICKER_PORT** in `AutoConnectDefs.h`.
- **Type**
- uint8_t
### tickerOn
Specifies the active logic level of the flicker signal. This value indicates the active signal level when driving the ticker.
- **Type**
- uint8_t
- **Value**
- LOWA flicker signal is an active-high.
- HIGHA flicker signal is an active-low.
### title
Set the menu title.
- **Type**
- String
## AutoConnectConfig example
```cpp
AutoConnect Portal;
AutoConnectConfig Config("", "passpass"); // SoftAp name is determined at runtime
Config.apid = ESP.hostname(); // Retrieve host name to SotAp identification
Config.apip = IPAddress(192,168,10,101); // Sets SoftAP IP address
Config.gateway = IPAddress(192,168,10,1); // Sets WLAN router IP address
Config.netmask = IPAddress(255,255,255,0); // Sets WLAN scope
Config.autoReconnect = true; // Enable auto-reconnect
Config.autoSave = AC_SAVECREDENTIAL_NEVER; // No save credential
Config.boundaryOffet = 64; // Reserve 64 bytes for the user data in EEPROM.
Config.portalTimeout = 60000; // Sets timeout value for the captive portal
Config.retainPortal = true; // Retains the portal function after timed-out
Config.homeUri = "/index.html"; // Sets home path of the sketch application
Config.title ="My menu"; // Customize the menu title
Config.staip = IPAddress(192,168,10,10); // Sets static IP
Config.staGateway = IPAddress(192,168,10,1); // Sets WiFi router address
Config.staNetmask = IPAddress(255,255,255,0); // Sets WLAN scope
Config.dns1 = IPAddress(192,168,10,1); // Sets primary DNS address
Portal.config(Config); // Configure AutoConnect
Portal.begin(); // Starts and behaves captive portal
```