<ahref="#after-connected-autoconnect-menu-performs-but-no-happens"title=" After connected, AutoConnect menu performs but no happens."class="md-nav__link">
After connected, AutoConnect menu performs but no happens.
</a>
</li>
<liclass="md-nav__item">
<ahref="#an-esp8266ap-as-softap-was-connected-but-captive-portal-does-not-start"title=" An esp8266ap as SoftAP was connected but Captive portal does not start."class="md-nav__link">
An esp8266ap as SoftAP was connected but Captive portal does not start.
</a>
</li>
<liclass="md-nav__item">
<ahref="#does-not-appear-esp8266ap-in-smartphone"title=" Does not appear esp8266ap in smartphone."class="md-nav__link">
<ahref="#after-connected-autoconnect-menu-performs-but-no-happens"title=" After connected, AutoConnect menu performs but no happens."class="md-nav__link">
After connected, AutoConnect menu performs but no happens.
</a>
</li>
<liclass="md-nav__item">
<ahref="#an-esp8266ap-as-softap-was-connected-but-captive-portal-does-not-start"title=" An esp8266ap as SoftAP was connected but Captive portal does not start."class="md-nav__link">
An esp8266ap as SoftAP was connected but Captive portal does not start.
</a>
</li>
<liclass="md-nav__item">
<ahref="#does-not-appear-esp8266ap-in-smartphone"title=" Does not appear esp8266ap in smartphone."class="md-nav__link">
<h2id="after-connected-autoconnect-menu-performs-but-no-happens"><iclass="fa fa-question-circle"></i> After connected, AutoConnect menu performs but no happens.<aclass="headerlink"href="#after-connected-autoconnect-menu-performs-but-no-happens"title="Permanent link">¶</a></h2>
<p>If you can access the <strong>AutoConnect root path</strong> as http://ESP8266IPADDRESS/_ac from browser, probably the sketch uses <em>ESP8266WebServer::handleClient()</em> without <ahref="api.html#handlerequest"><em>AutoConnect::handleRequest()</em></a>.<br/>
For AutoConnect menus to work properly, call <ahref="api.html#handlerequest"><em>AutoConnect::handleRequest()</em></a> after <em>ESP8266WebServer::handleClient()</em> invoked, or use <ahref="api.html#handleclient"><em>AutoConnect::handleClient()</em></a>. <ahref="api.html#handleclient"><em>AutoConnect::handleClient()</em></a> is equivalent <em>ESP8266WebServer::handleClient</em> combined <ahref="api.html#handlerequest"><em>AutoConnect::handleRequest()</em></a>.</p>
<p>See also the explanation <ahref="basicusage.html#esp8266webserver-hosted-or-parasitic">here</a>.</p>
<h2id="an-esp8266ap-as-softap-was-connected-but-captive-portal-does-not-start"><iclass="fa fa-question-circle"></i> An esp8266ap as SoftAP was connected but Captive portal does not start.<aclass="headerlink"href="#an-esp8266ap-as-softap-was-connected-but-captive-portal-does-not-start"title="Permanent link">¶</a></h2>
<p>Captive portal detection could not be trapped. It is necessary to disconnect and reset ESP8266 to clear memorized connection data in ESP8266. Also, It may be displayed on the smartphone if the connection information of esp8266ap is wrong. In that case, delete the connection information of esp8266ap memorized by the smartphone once.</p>
<h2id="does-not-appear-esp8266ap-in-smartphone"><iclass="fa fa-question-circle"></i> Does not appear esp8266ap in smartphone.<aclass="headerlink"href="#does-not-appear-esp8266ap-in-smartphone"title="Permanent link">¶</a></h2>
<p>Maybe it is successfully connected at the <strong>first WiFi.begin</strong>. ESP8266 remembers the last SSID successfully connected and will use at the next. It means SoftAP will only start up when the first <em>WiFi.begin()</em> fails.</p>
<p>The saved SSID would be cleared by <em>WiFi.disconnect()</em> with WIFI_STA mode. If you do not want automatic reconnection, you can erase the memorized SSID with the following simple sketch.</p>
<detailsclass="hint"><summary>You can interactively check the WiFi state of ESP8266.</summary><p>Please try <ahref="https://github.com/Hieromon/ESPShaker"><strong>ESPShaker</strong></a>. It is ESP8266 interactive serial command processor.</p>
<p><imgsrc="./images/espshaker.gif"/></p>
</details>
<h2id="does-not-response-from-95ac"><iclass="fa fa-question-circle"></i> Does not response from /_ac.<aclass="headerlink"href="#does-not-response-from-95ac"title="Permanent link">¶</a></h2>
<p>Probably <strong>WiFi.begin</strong> failed with the specified SSID. Activating the <ahref="advancedusage.html#debug-print">debug printing</a> will help you to track down the cause.</p>
<h2id="how-change-esp8266ap-for-ssid-name-in-captive-portal"><iclass="fa fa-question-circle"></i> How change esp8266ap for SSID name in Captive portal?<aclass="headerlink"href="#how-change-esp8266ap-for-ssid-name-in-captive-portal"title="Permanent link">¶</a></h2>
<p>An <strong>esp8266ap</strong> is default SSID name for SoftAP of captive portal and password is <strong>12345678</strong>. You can change both by using <ahref="api.html#autoconnectconfig-api">AutoConnectConfig</a>.</p>
<h2id="how-change-http-port"><iclass="fa fa-question-circle"></i> How change HTTP port?<aclass="headerlink"href="#how-change-http-port"title="Permanent link">¶</a></h2>
<p>HTTP port number is defined as a macro in <ahref="https://github.com/Hieromon/AutoConnect/blob/77d5cb5dc6d50651fd15f74b47859105c71fc317/src/AutoConnect.h#L89">AutoConnect.h</a> header file. You can change it directly with several editors and must re-compile.</p>
<h2id="hang-up-after-reset"><iclass="fa fa-question-circle"></i> Hang up after Reset?<aclass="headerlink"href="#hang-up-after-reset"title="Permanent link">¶</a></h2>
<p>If ESP8266 hang up after reset by AutoConnect menu, perhaps manual reset is not yet. Especially if it is not manual reset yet after uploading the sketch, the boot mode will stay 'Uart Download'. There is some discussion about this on the Github's ESP8266 core: <ahref="https://github.com/esp8266/Arduino/issues/1017">https://github.com/esp8266/Arduino/issues/1017</a></p>
<p>If you received the following message, the boot mode is still sketch uploaded. It needs to the manual reset once.</p>
<p>It is described by <ahref="view-source:https://www.espressif.com/en/products/hardware/esp8266ex/resources">ESP8266 Non-OS SDK API Reference</a>, section A.5.</p>
<table>
<thead>
<tr>
<th>Messages</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>rst cause</td>
<td>1: power on<br>2: external reset<br>4: hardware watchdog reset</td>
</tr>
<tr>
<td>boot mode<br>(the first parameter)</td>
<td>1: ESP8266 is in UART-down mode (and downloads firmware into flash).<br>3: ESP8266 is in Flash-boot mode (and boots up from flash).</td>
<h2id="how-erase-the-credentials-saved-in-eeprom"><iclass="fa fa-question-circle"></i> How erase the credentials saved in EEPROM?<aclass="headerlink"href="#how-erase-the-credentials-saved-in-eeprom"title="Permanent link">¶</a></h2>
<p>Make some sketches for erasing the EEPROM area, or some erasing utility is needed. You can prepare the sketch to erase the saved credential with <em>AutoConnectCredential</em>. The <em>AutoConnectCrendential</em> class provides the access method to the saved credential in EEPROM and library source file is including it.</p>
<p>AutoConnectCredential default constructor. The default offset value is 0. If the offset value is 0, the credential storage area starts from the top of the EEPROM. AutoConnect sometimes overwrites data when using this area with user sketch.</p>
A data structure of the credential saving area in EEPROM as the below. <supid="fnref:1"><aclass="footnote-ref"href="#fn:1"rel="footnote">1</a></sup></li>
</ul>
<table>
<thead>
<tr>
<th>Byte offset</th>
<th>Length</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>0</td>
<td>8</td>
<td>AC_CREDT</td>
</tr>
<tr>
<td>8</td>
<td>1</td>
<td>Number of contained entries (uint8_t)</td>
</tr>
<tr>
<td>9</td>
<td>2</td>
<td>Container size, excluding size of AC_CREDT and size of the number of entries(width for uint16_t type).</td>
</tr>
<tr>
<td>11</td>
<td>variable</td>
<td>SSID terminated by 0x00. Max length is 32 bytes.</td>
</tr>
<tr>
<td>variable</td>
<td>variable</td>
<td>Password plain text terminated by 0x00. Max length is 64 bytes.</td>
</tr>
<tr>
<td>variable</td>
<td>6</td>
<td>BSSID</td>
</tr>
<tr>
<td>variable</td>
<td></td>
<td>Contained the next entries. (Continuation SSID+Password+BSSID)</td>
</tr>
<tr>
<td>variable</td>
<td>1</td>
<td>0x00. End of container.</td>
</tr>
</tbody>
</table>
<divclass="admonition hint">
<pclass="admonition-title">Hint</p>
<p>With the <ahref="https://github.com/Hieromon/ESPShaker"><strong>ESPShaker</strong></a>, you can access EEPROM interactively from the serial monitor, and of course you can erase saved credentials.</p>
</div>
<h2id="how-locate-the-link-button-to-the-autoconnect-menu"><iclass="fa fa-question-circle"></i> How locate the link button to the AutoConnect menu?<aclass="headerlink"href="#how-locate-the-link-button-to-the-autoconnect-menu"title="Permanent link">¶</a></h2>
<p>Link button to AutoConnect menu can be embedded into Sketch's web page. The root path of the menu is <strong>/_ac</strong> by default and embed the following <code><a></a></code> tag in the generating HTML.</p>
<h2id="how-much-memory-does-autoconnect-consume"><iclass="fa fa-question-circle"></i> How much memory does AutoConnect consume?<aclass="headerlink"href="#how-much-memory-does-autoconnect-consume"title="Permanent link">¶</a></h2>
<p>It increases about 53K bytes compared to the case without AutoConnect. A sketch size of the most simple example introduced in the Getting started is about 330K bytes. (270K byte without AutoConnect)</p>
<p>It consumes about 2K bytes in the static and about 12K bytes are consumed at the moment when menu executed.</p>
<h2id="i-cannot-complete-to-wi-fi-login-from-smartphone"><iclass="fa fa-question-circle"></i> I cannot complete to Wi-Fi login from smartphone.<aclass="headerlink"href="#i-cannot-complete-to-wi-fi-login-from-smartphone"title="Permanent link">¶</a></h2>
<p>Because AutoConnect does not send a login success response to the captive portal requests from the smartphone. The login success response varies iOS, Android and Windows. By analyzing the request URL of different login success inquiries for each OS, the correct behavior can be implemented, but not yet. Please resets ESP8266 from the AutoConnect menu.</p>
<h2id="i-cannot-see-the-custom-web-page"><iclass="fa fa-question-circle"></i> I cannot see the custom Web page.<aclass="headerlink"href="#i-cannot-see-the-custom-web-page"title="Permanent link">¶</a></h2>
<p>If the sketch is correct, a JSON syntax error may have occurred. In this case, activate the <ahref="faq.html#3-turn-on-the-debug-log-options">AC_DEBUG</a> and rerun. If you take the message of JSON syntax error, the <ahref="https://arduinojson.org/v5/assistant/">Json Assistant</a> helps syntax checking. This online tool is provided by the author of ArduinoJson and is most consistent for the AutoConnect. </p>
<h2id="autoconnect-behaves-not-stable-with-my-sketch-yet"><iclass="fa fa-question-circle"></i> AutoConnect behaves not stable with my sketch yet.<aclass="headerlink"href="#autoconnect-behaves-not-stable-with-my-sketch-yet"title="Permanent link">¶</a></h2>
<p>If AutoConnect behavior is not stable with your sketch, you can try the following measures.</p>
<p>Both ESP8266 and ESP32 can only work on one channel at any given moment, this will cause loss of connection on the channel where your station operates the captive portal. If the channel of the AP which you want to connect is different from the SoftAP channel, the operation of the captive portal will not respond with the screen of the AutoConnect connection attempt remains displayed. In such a case please try the <ahref="apiconfig.html#autoconnectconfig">AutoConnectConfig</a> to match the <ahref="apiconfig.html#channel">channel</a> to the access point.</p>
<p>To stabilize the behavior, You can select the <ahref="http://lwip.wikia.com/wiki/LwIP_Wiki">lwIP</a> variant to contribute. Lower memory option of Arduino IDE for core version 2.4.2 is based on the lwIP-v2. On the other hand, the core version 2.5.0 upstream is based on the lwIP-2.1.2 stable release.</p>
<p>You can select the option from Arduino IDE as <strong>Tool</strong> menu, if you are using ESP8266 core 2.5.0. It can be select <code>lwIP v2 Lower Memory</code> option. (not <code>lwIP v2 Lower Memory (no features)</code>) It is expected to improve response performance and stability.</p>
<p>The <ahref="https://github.com/espressif/arduino-esp32">arduino-esp32</a> is still under development even if it is a stable release. It is necessary to judge whether the cause of the problem is the core or AutoConnect. Trace the log with the esp32 core and the AutoConnect debug option enabled for problem diagnosis and please you check the <ahref="https://github.com/espressif/arduino-esp32/issues">issue of arduino-esp32</a>. The problem that your sketch possesses may already have been solved.</p>
<h3id="3-turn-on-the-debug-log-options">3. Turn on the debug log options<aclass="headerlink"href="#3-turn-on-the-debug-log-options"title="Permanent link">¶</a></h3>
<p>To fully enable for the AutoConnect debug logging options, change the following two files.</p>
<h3id="4-reports-the-issue-to-autoconnect-repository-on-github">4. Reports the issue to AutoConnect repository on Github<aclass="headerlink"href="#4-reports-the-issue-to-autoconnect-repository-on-github"title="Permanent link">¶</a></h3>
<p>If you can not solve AutoConnect problems please report to <ahref="https://github.com/Hieromon/AutoConnect/issues">Issues</a>. And please make your question comprehensively, not a statement. Include all relevant information as follows.</p>
<ul>
<li>Hardware module</li>
<li>Arduino core Version (including the upstream tag ID.)</li>
<li>Operating System which you use</li>
<li>lwIP variant</li>
<li>Problem description</li>
<li>If you have a STACK DUMP decoded result with formatted by the code block tag</li>
<li>The sketch code with formatted by the code block tag</li>
<p>There may be 0xff as an invalid data in the credential saving area. The 0xff area would be reused. <aclass="footnote-backref"href="#fnref:1"rev="footnote"title="Jump back to footnote 1 in the text">↩</a></p>
<p><code>PageBuilder.h</code> file exists in the <code>libraries/PageBuilder/src</code> directory under your sketch folder. <aclass="footnote-backref"href="#fnref:2"rev="footnote"title="Jump back to footnote 2 in the text">↩</a></p>